GAS/ELECTRIC RANGE
for residential use only
THIS RANGE IS FOR RESIDENTIAL USE ONLY
FOR INSTALLER ONLY
Some models are supplied with a protective lm on steel and aluminium
parts. This lm must be removed before installing/using the appliance.
Models: VEFSGE 304 SC..
INSTALLATION INSTRUCTIONS
IMPORTANT - PLEASE READ AND FOLLOW
• Beforebeginning,pleasereadtheseinstructionscompletelyandcarefully.
• Donotremovepermanentlyafxedlabels,warnings,orplatesfromtheproduct.Thismay
voidthewarranty.
• Pleaseobservealllocalandnationalcodesandordinances.
• Pleaseensurethatthisproductisproperlygrounded.
The installer should leave these instructions with the consumer who should retain
for local inspectors use and for future reference.
Installationmustconformwithlocalcodesorintheabsenceofcodes,theNationalFuelGas
CodeANSIZ223.1/NFPA54-Iatestedition.Electricalinstallationmustbeinaccordancewith
theNationalElectricalCode,ANSI/NFPA70-latesteditionand/orlocalcodes.
INCANADA:InstallationmustbeinaccordancewiththecurrentCAN/CGA-B149.1National
GasInstallationCodeorCAN/CGA-B149.2,PropaneInstallationCodeand/orlocalcodes.
ElectricalinstallationmustbeinaccordancewiththecurrentCSAC22.1CanadianElectrical
CodesPart1and/orlocalcodes.
INSTALLATIONINMANUFACTURED(MOBILE)HOME:Theinstallationmustconformwith
theManufacturedHomeConstructionandSafetyStandard,Title24CFR,Part3280[formerly
theFederalStandardforMobileHomeConstructionandSafety,Title24,HUD(Part280)]
or,whensuchstandardisnotapplicable,theStandardforManufacturedHomeInstallations,
ANSI/NCSBCSA225.1,orwithlocalcodeswhereapplicable.
INSTALLATIONINRECREATIONALPARKTRAILERS:Theinstallationmustconformwith
stateorothercodesor,intheabsenceofsuchcodes,withtheStandardforRecreational
ParkTrailers,ANSIA119.5.
Installation of any gas-red equipment should be made by a licensed plumber.A manual
shut-offvalvemustbeinstalledinanaccessiblelocationinthegaslineexternaltotheap-
plianceforthepurposeofturningonorshuttingoffgastotheappliance(InMassachusetts
suchshutoffdevicesshouldbeapprovedbytheBoardofStateExaminersofPlumbers&
GasFitters).
Ifanexternalelectricalsourceisutilized,theappliance,wheninstalled,mustbeelectrically
groundedinaccordancewithlocalcodesor,intheabsenceoflocalcodes,withthenational
ElectricalCode,ANSI/NFPA70.
R
Vue de la page 0
1 2 3 4 5 6 ... 23 24

Résumé du contenu

Page 1 - GAS/ELECTRIC RANGE

GAS/ELECTRIC RANGEfor residential use onlyTHIS RANGE IS FOR RESIDENTIAL USE ONLYFOR INSTALLER ONLYSome models are supplied with a protective l

Page 2 - WARNING !

101LEVELLING THE RANGETherangeisequippedwith4LEVELLINGFEETandmaybelevelledbyscrewingorunscrewingthefeet(gs.1.6-1.7).Itisimport

Page 3 - DATAPLATE

111INSTALLING THE COOKTOP FRONT GUARDToincreasetheclearancebetweenthefrontedgeofthecooktopandtheburnersitispossibletoinstallthecoo

Page 4 - INSTALLATION INSTRUCTIONS

12gas connection22. Pressure Regulator:a. Allheavyduty,commercialtypecookingequipmentmusthaveapressureregulatorontheincomingserviceli

Page 5 - WARNING!!

132LOCKArrowPRESSURE REGULATOR INSTALLATIONSTEP 1Mountthe1/2”NPT(conical)maleconnectortothepressureregulatorandtightenbyusingawrench.D

Page 6 - PROXIMITY TO SIDE CABINETS

142Fig. 2.4GAS CONNECTION SPEFICICATIONRangemanifoldManifold male pipe tting1/2”Gcylindrical(ISO228-1)male1/2”Gcylindrical(ISO228-1)femaleGas

Page 7 - ASSEMBLING THE BACKGUARD

152b. Anyconversionrequiredmustbeperformedbyyourdealeroraqualiedlicen-sedtechnicianorgasservicecompany.Pleaseprovidetheservice

Page 8 - STANDARD INSTALLATION

162Pressureregulator 12NATURAL GASREGULATIONLP/PROPANEREGULATIONAREGULATOR COVERCONVERSION TO LP/PROPANE GAS (OR CONVERSION BACK TO THE ORIGINAL GAS -

Page 9 - ISLAND INSTALLATION

172OPERATIONS TO BE PERFORMED WHEN SUBSTITUTING THE INJECTORS• Removethepansupports,theburnercapsandtheamespreaders.• Dualburneronly(

Page 10 - TIPPING

18Fig. 2.10R1 Regulationscrew(Semirapidburner)R2 Regulationscrew(Innercrownofdualburner)R3 Regulationscrew(Outercrownofdualburner)R1

Page 11

19electrical connection3 WARNINGTO AVOID ELECTRICAL SHOCK HA-ZARD, BEFORE INSTALLING THE APPLIANCE, SWITCH POWER OFF AT THE

Page 12 - 2. Pressure Regulator:

2WARNING !To reduce the risk of tipping the appliance, the appliance must be secured by properly installed anti-tip device packed with the applianc

Page 13

2033-Wire Power Cord Installation(SeeFigure3.2)1. RemovetheTerminal Block Access Plateonthebackoftherangebyunscrewingthe4xingScrews

Page 14 - GAS CONNECTION SPEFICICATION

2133-Wire Conduit Installation (SeeFigure3.5)1. RemovetheTerminal Block Access Plateonthebackoftherangebyunscrewingthe4xingScrews(F

Page 15 - 4. Rigid Pipe Connections:

223WIRING DIAGRAMELECTRIC DIAGRAM KEYIC IGNITIONCOILISG IGNITIONSWITCHESGROUPOL OVENLAMPE61 RELAYCE CIRCULARELEMENTGE BROILELEMENTTE TOP

Page 17 - INJECTORS TABLE

Themanufacturercannotbeheldresponsibleforpossibleinaccuraciesduetoprin-tingortranscriptionerrorsinthepresentbooklet.Themanufacturer

Page 18 - LO”position(minimumrate)

3Thisapplianceisdesignedandmanufacturedsolelyforthecookingofdomestic(household)foodandinnotsuitableforanynonedomesticapplication

Page 19 - ELECTRICAL REQUIREMENTS

4INSTALLATION INSTRUCTIONSWARNING!THIS APPLIANCE MUST BE INSTALLED BY A QUALIFIED INSTALLER.Improper installation, adjustment, alteration, services, o

Page 20 - Access Plate

5GENERAL INFORMATION1. Installation must conform with local codes or,in the absen-ceof local codes, with the National Fuel Gas Code,A

Page 21

6PROXIMITY TO SIDE CABINETS1. Thisrangemaybeinstalleddirectlyadjacenttoexisting36”(914mm)highbasecabinets. Rangedimensions:• width:

Page 22 - WIRING DIAGRAM

7AABASSEMBLING THE BACKGUARDIt is mandatory to install the backguard.Assemblethebackguardasshowningure1.3:• Screwthe2screws“A”interposin

Page 23

8BGEDCFAABCEDFGAAPROXIMITY TO SIDE CABINETSSTANDARD INSTALLATIONFig. 1.4bFig. 1.4aOVEN VENTRef. inch mmA 0” 0B 36” 914C 11”13/16 300D 30”minimum 762

Page 24

9PROXIMITY TO SIDE CABINETSISLAND INSTALLATIONAABGEDFCHAABGEDFCHFig. 1.5bFig. 1.5aOVEN VENTRef. inch mmA 0” 0B 36” 914C 11”13/16 300D 30”minimum 762